Have had this smoker for around 3 years has been working great well maintained and cleaned regularly, but I’m having temp issues shown in the pictures, internal thermometer gets cleaned, ash pit vacuumed. I’m at a loss
by Dangerous-Rip534
1 Comment
tribaldragon73
Consider replacing your RTD sensor probe if you’ve exposed it to high temps, such as a flare up. I’ve had to replace mine twice already due to grease fires. I got my part right from the manufacturer of my grill for around $30, and I’ve seen them on Amazon for about half that. I’ve never had to mess around with my auger settings, but you could try playing around with that a bit, just remember what settings you are on now so you can switch back if it doesn’t seem to help.
1 Comment
Consider replacing your RTD sensor probe if you’ve exposed it to high temps, such as a flare up. I’ve had to replace mine twice already due to grease fires. I got my part right from the manufacturer of my grill for around $30, and I’ve seen them on Amazon for about half that.
I’ve never had to mess around with my auger settings, but you could try playing around with that a bit, just remember what settings you are on now so you can switch back if it doesn’t seem to help.